# How Refrigeration Works

> On 5 November 2026 the FBI and the US cybersecurity agency CISA warned that attackers were tampering with internet-connected refrigeration controllers, after hundreds of supermarkets and three blood-storage sites in Europe saw their cold rooms warm up. This film explains the established physics behind the machines being protected: why heat only flows from hot to cold on its own, why evaporation cools, how the four parts of the vapour-compression cycle move heat out of a box, why a heat pump is the same machine run the other way, how refrigeration grew from the ice trade to the home fridge, why its refrigerants had to change twice, and how much of the world's food, medicine and electricity now depends on it.

Interactive film: https://www.planetpast.com/stories/how-refrigeration-works/  
Publisher: PlanetPast (https://www.planetpast.com/) · d => T('readPublished', l, { d: dateIn(d, l) }) 2026-11-08 · Technology, Physics, Chemistry

## Prologue

### Guarding the cold
*Technology · Physics*

Why a warning about fridges made the news.

On the third of November 2026, France’s blood service said the settings at three of its blood stores had been quietly changed. Two days later, the FBI and the US cybersecurity agency CISA warned that attackers were targeting refrigeration controllers, the small boxes that set a fridge’s temperature, if they can be reached from the internet. Hundreds of French supermarkets had already been hit. No attacker has been named. To see why that matters, look at what a fridge really does. It does not make cold. It moves heat.

![Bags of blood are kept chilled on wire shelves; a controller on the side holds the temperature. AI-generated illustration.](https://assets.planetpast.com/a/2a/2aafe3462dbaf5a3.jpg)

![A refrigeration controller with its network cable: the target named in the advisory. AI-generated illustration.](https://assets.planetpast.com/a/01/01858759148e8336.jpg)

- **250–350**: French supermarkets hit in October (estimate)
- **115+**: stores in six countries in a second wave, November

> “Every organization that depends on refrigeration and monitoring systems should assume it could be a target.” (Chris Butera, CISA)

Prologue

#### The news

BleepingComputer (5 November 2026) and Help Net Security (6 November 2026): CISA and the FBI, with HHS, USDA and DOT, warned that internet-exposed or unpatched refrigeration and temperature controllers in retail grocery, cold storage, healthcare, food and agriculture, chemical and transport are being targeted. Attackers who reach them can change setpoints or force heating or defrost, causing inventory loss. In October, controllers at an estimated 250–350 French supermarkets were compromised; in November a second wave hit more than 115 stores in six European countries; on 3 November France’s blood service (EFS) said settings were changed at three blood-storage facilities.

Who is behind it has not been identified: France’s cyber agency ANSSI says it has no specific information on any threat actor (Cybersecurity Dive).

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [BleepingComputer (5 Nov 2026): FBI, CISA warn of cyberattacks targeting refrigeration systems](https://www.bleepingcomputer.com/news/security/fbi-cisa-warn-of-cyberattacks-targeting-refrigeration-systems/); [Help Net Security (6 Nov 2026): US agencies warn attackers are targeting refrigeration systems that protect food and medicine](https://www.helpnetsecurity.com/2026/11/06/cyberattacks-refrigeration-systems-cisa-fbi/); [Cybersecurity Dive: refrigeration attacks in France](https://www.cybersecuritydive.com/news/refrigeration-france-cyber/832858/)

## Chapter I · Heat runs downhill

### Heat runs downhill
*Chapter I · Heat runs downhill*

The one-way rule a fridge has to break.

Put an ice cube next to a hot cup of tea, and heat flows one way only: from the hot tea to the cold ice. That is the second law of thermodynamics. On its own, heat never flows from cold to hot. Yet a refrigerator does exactly that. It takes heat out of a cool box and pushes it into a warmer kitchen. To push heat uphill like that, it has to do work, paid for with electricity.

![Tea and ice end at one temperature, never the reverse. AI-generated illustration.](https://assets.planetpast.com/a/b6/b6ee09e4d9cbaf56.jpg)

- on its own: heat flows hot → cold
- to move it cold → hot needs work
- fridges, air conditioners and heat pumps all pay that work

![Cold inside, warm coils at the back: the heat is carried out, not destroyed. AI-generated illustration.](https://assets.planetpast.com/a/2f/2f40413370ec722d.jpg)

$$Q_h = Q_c + W$$
- $Q_h$: heat released into the kitchen
- $Q_c$: heat taken from inside the box
- $W$: electrical work put in

Chapter I · Heat runs downhill

#### The second law

OpenStax College Physics 15.5: heat naturally flows from hot to cold. Refrigerators, air conditioners and heat pumps are heat engines run backward: they move heat from cold to hot, which requires work input, as the second law of thermodynamics demands. Penn State EGEE 102 calls a fridge a “heat mover”: it takes thermal energy from the cool interior and releases it into the warmer kitchen.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [OpenStax College Physics 15.5: Heat pumps and refrigerators](https://openstax.org/books/college-physics/pages/15-5-applications-of-thermodynamics-heat-pumps-and-refrigerators); [Penn State EGEE 102, 6.4: Refrigerators](https://courses.ems.psu.edu/egee102/node/2402)

### Evaporation cools
*Chapter I · Heat runs downhill*

Turning liquid into gas soaks up heat.

The trick a fridge uses is one your body uses too. When sweat evaporates, it carries heat away from your skin. Turning a liquid into a gas takes a lot of energy, called latent heat, and the liquid takes it from whatever it touches. Boiling is the same change, all through the liquid at once. While it lasts, the temperature holds steady.

![Every wisp of vapour leaving a wet surface takes heat with it. AI-generated illustration.](https://assets.planetpast.com/a/00/007de4e5459ce5b4.jpg)

$$Q = m\,L_v$$
- $Q$: heat taken in
- $m$: mass that evaporates
- $L_v$: latent heat of vaporisation

- **2,430 kJ/kg**: to evaporate at 37 °C
- **2,256 kJ/kg**: to boil at 100 °C

Chapter I · Heat runs downhill

#### Latent heat

OpenStax College Physics 14.3: the latent heat of vaporisation of water is 2,256 kJ/kg at 100 °C and about 2,430 kJ/kg at 37 °C, which is why evaporating sweat cools the skin. Penn State EGEE 102: evaporation needs energy, which a fridge’s refrigerant takes as heat from the interior; its temperature stays constant while it changes phase.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [OpenStax College Physics 2e, 14.3: Phase change and latent heat](https://openstax.org/books/college-physics-ap-courses-2e/pages/14-3-phase-change-and-latent-heat); [Penn State EGEE 102, 6.4: Refrigerators](https://courses.ems.psu.edu/egee102/node/2402)

### Squeeze it, and it boils hotter
*Chapter I · Heat runs downhill*

The boiling point is not fixed.

One more key. A liquid boils when the push of its own vapour, its vapour pressure, matches the pressure around it. So its boiling point depends on pressure. Raise the pressure and it boils hotter: that is how a pressure cooker works. Lower the pressure and the same liquid boils colder. A refrigerant is a liquid chosen to boil at a low temperature when its pressure is low, and to turn back into liquid when it is squeezed.

![Higher pressure inside lets water get hotter before it boils. AI-generated illustration.](https://assets.planetpast.com/a/f0/f0cb957f17f8621a.jpg)

- **100 °C**: at 1 atmosphere, sea level
- **higher**: inside a pressure cooker

- boils cold at low pressure: inside the box
- condenses warm at high pressure: at the back
- goes round the loop again and again

Chapter I · Heat runs downhill

#### Boiling and pressure

OpenStax University Physics vol. 2, 1.5: a liquid boils when its vapour pressure equals the surrounding pressure, so the boiling point rises with pressure and falls when the pressure drops. Water boils at 100 °C at 1 atm, and hotter at higher pressure; pressure cookers use this. Britannica and Penn State: in a fridge, the refrigerant evaporates at low pressure inside the cabinet and condenses at high pressure outside it.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [OpenStax University Physics vol. 2, 1.5: Phase changes](https://openstax.org/books/university-physics-volume-2/pages/1-5-phase-changes); [Britannica: Refrigeration](https://www.britannica.com/technology/refrigeration); [Penn State EGEE 102, 6.4: Refrigerators](https://courses.ems.psu.edu/egee102/node/2402)

## Chapter II · The loop

### Four parts, one loop
*Chapter II · The loop*

The vapour-compression cycle.

A fridge puts these ideas into a sealed loop with four parts: a compressor, a condenser, an expansion valve and an evaporator. The same refrigerant goes round and round, picking up heat inside the box and dropping it outside. Let us follow it once round.

![A cutaway: the cold compartment, the coil grid behind, the compressor below. AI-generated illustration.](https://assets.planetpast.com/a/2f/2f40413370ec722d.jpg)

- 1 compressor: squeezes the gas
- 2 condenser: gives heat to the room
- 3 expansion valve: drops the pressure
- 4 evaporator: boils and takes heat

Chapter II · The loop

#### The vapour-compression cycle

Britannica and Penn State EGEE 102: the cycle has four parts, compressor, condenser, expansion valve and evaporator, linked in a closed loop. The refrigerant evaporates inside the cabinet, absorbing heat, and condenses outside it, releasing heat. In the 3D model the beads are coloured by temperature, and bigger beads mark liquid.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [Britannica: Refrigeration](https://www.britannica.com/technology/refrigeration); [Penn State EGEE 102, 6.4: Refrigerators](https://courses.ems.psu.edu/egee102/node/2402)

### Squeeze, then shed the heat
*Chapter II · The loop*

Why the back of a fridge is warm.

Start at the compressor, at the bottom back of the fridge. It squeezes the refrigerant gas, raising its pressure and temperature. This is the part that uses most of the electricity. The hot gas flows into the condenser, the grid of coils at the back. Now hotter than the kitchen, it gives its heat to the room and condenses into a liquid. That warmth at the back of your fridge is heat taken out of your food.

![A sealed dome holds the pump and its motor; copper pipes carry the gas in and out. AI-generated illustration.](https://assets.planetpast.com/a/0d/0d07fc98c39e7916.jpg)

- **↑ pressure**: and ↑ temperature of the gas
- **#1**: user of the fridge’s electricity

- in: hot, high-pressure gas
- heat flows out to the cooler room
- out: warm, high-pressure liquid

![The condenser on the back: one long tube wound through a grid of thin wire fins. AI-generated illustration.](https://assets.planetpast.com/a/5e/5e4e19545589e69f.jpg)

Chapter II · The loop

#### Compressor and condenser

Penn State EGEE 102: the compressor compresses the refrigerant gas, raising its pressure and temperature, and is the main electricity user. The condenser coils on the back give the heat to the room, and the refrigerant condenses to a liquid.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [Penn State EGEE 102, 6.4: Refrigerators](https://courses.ems.psu.edu/egee102/node/2402); [Britannica: Refrigeration](https://www.britannica.com/technology/refrigeration)

### Let go, and boil
*Chapter II · The loop*

Where the cold actually happens.

The warm liquid now passes through the expansion valve into a low-pressure zone. At the lower pressure some of it boils at once, taking the heat it needs from itself, so it cools sharply. The cold refrigerant enters the evaporator inside the box. There it boils, taking latent heat from the food and the air. Open the door and warm air floods in. Change the setpoint, and the loop simply stops carrying enough heat away: the warmth wins. Then the gas returns to the compressor.

![Frost forms on the evaporator plate, the coldest surface in the fridge. AI-generated illustration.](https://assets.planetpast.com/a/21/217eb9efd87daeb2.jpg)

- in: cold, low-pressure liquid
- boils at a steady temperature
- out: cool gas, back to the compressor

![Cold air spills out across the floor and warm kitchen air takes its place. AI-generated illustration.](https://assets.planetpast.com/a/34/3492103e0addf1c0.jpg)

Chapter II · The loop

#### Valve and evaporator

Penn State EGEE 102: the high-pressure liquid expands through the expansion valve into a low-pressure zone and cools. In the evaporator inside the fridge it evaporates, absorbing heat from the food and air, then returns to the compressor.

The open-door and changed-setpoint effects in the model are illustrative only.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [Penn State EGEE 102, 6.4: Refrigerators](https://courses.ems.psu.edu/egee102/node/2402); [Britannica: Refrigeration](https://www.britannica.com/technology/refrigeration)

### Run it the other way
*Chapter II · The loop*

How good a fridge is, and the heat pump.

How well does it work? Divide the heat moved by the electrical work put in: that is the coefficient of performance. Real fridges and air conditioners reach two to six. That is not free energy: they only move heat that is already there. Now put the cold coil outdoors and the hot coil inside. Even cool outdoor air still holds heat, so the same loop can carry it into a home. That is a heat pump.

$$\mathrm{COP} = \dfrac{Q_c}{W}$$
- $Q_c$: heat removed from the cold side
- $W$: work put in

- **2–6**: COP of refrigerators and air conditioners
- **2–4**: COP of real heat pumps

![A heat pump’s outdoor unit: here its coil is the cold side of the loop. AI-generated illustration.](https://assets.planetpast.com/a/45/45c14d147613f1e4.jpg)

Chapter II · The loop

#### COP and heat pumps

OpenStax College Physics 15.5: for a refrigerator COP = heat removed ÷ work; for a heat pump COP = heat delivered ÷ work, and at the same two temperatures the refrigerator’s COP is one less than the heat pump’s. Real heat pumps run at about 2–4, real air conditioners and refrigerators at 2–6. A heat pump is the same cycle used for heating, “essentially an air conditioner and a heating unit all in one.”

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [OpenStax College Physics 15.5: Heat pumps and refrigerators](https://openstax.org/books/college-physics/pages/15-5-applications-of-thermodynamics-heat-pumps-and-refrigerators)

## Chapter III · Before the fridge

### Selling winter
*Chapter III · Before the fridge*

The ice trade.

Before machines, cold was cut from frozen lakes. In 1806, the Boston merchant Frederic Tudor shipped his first cargo of ice to the Caribbean. He lost money, but the trade grew: by 1846, some sixty-five thousand tons of ice a year left Boston.

![Blocks were sawn from frozen ponds in winter and stored in sawdust. AI-generated illustration.](https://assets.planetpast.com/a/26/264fd1e072fc32bc.jpg)

![Tudor’s first cargo sailed on a brig and lost him $4,500. AI-generated illustration.](https://assets.planetpast.com/a/09/09d401bfa88766ef.jpg)

- 1826: ≈4,000
- 1846: ≈65,000

- **180 tons**: of New England ice shipped to Calcutta in 1833

Chapter III · Before the fridge

#### The ice trade

HistoryNet: Frederic Tudor’s first ice shipment sailed on 10 February 1806 on the brig Favorite to St. Pierre, Martinique, and lost $4,500. Ice exports from Boston were about 4,000 tons a year in 1826 and about 65,000 tons in 1846; in 1833 a cargo of 180 tons went to Calcutta.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [HistoryNet: how pioneering entrepreneurs helped 19th-century America keep cool](https://www.historynet.com/how-pioneering-entrepreneurs-helped-19th-century-america-keep-cool/)

### Cold on demand
*Chapter III · Before the fridge*

The first machines.

Long before the ice trade, cold had been made in a laboratory. In the 1740s, William Cullen at Glasgow chilled a liquid by letting it evaporate in a partial vacuum. In 1834, Jacob Perkins patented in England the first working machine to use the vapour-compression cycle. In the 1840s, a Florida doctor, John Gorrie, cooled the rooms of fever patients, and in 1851 he patented an ice machine.

![An engraving-style sketch of evaporation cooling water in a bell jar. AI-generated illustration.](https://assets.planetpast.com/a/2b/2bf3670790fb24d8.jpg)

- 1748: Cullen, Glasgow: ether boiled in a vacuum (Britannica)
- 1834: Perkins: vapour-compression patent (ASME)
- 1851: Gorrie: US patent No. 8080

![An early ice machine in engraving style: a hand crank, iron cylinders and a tub. AI-generated illustration.](https://assets.planetpast.com/a/2a/2ad8e0f839b8dba3.jpg)

Chapter III · Before the fridge

#### The first machines

Britannica dates William Cullen’s first known artificial refrigeration to 1748 at Glasgow, when ethyl ether boiled into a partial vacuum; the International Institute of Refrigeration dates his ice demonstration to 1755. ASME dates Jacob Perkins’s English patent to 1834 and calls it the first working vapour-compression device (the IIR note gives 1835). The Smithsonian: John Gorrie’s US Patent No. 8080, 6 May 1851, was the first US patent for a mechanical ice-making machine; it compressed and expanded air, and Gorrie used ice and cooled air to treat tropical disease. Britannica: Gorrie, a Florida physician, cooled the rooms of patients with fever in the 1840s and patented his ice machine in 1851.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [Britannica: Refrigeration](https://www.britannica.com/technology/refrigeration); [International Institute of Refrigeration: A brief history of refrigeration (PDF)](https://efriarc.pt/wp-content/uploads/2022/09/IIR_A-Brief-History-of-Refrigeration.pdf); [ASME Landmark 274: Perkins vapour-compression cycle for refrigeration](https://www.asme.org/about-asme/engineering-history/landmarks/274-perkins-vapor-compression-cycle-for-refrigeration); [Smithsonian National Museum of American History: Gorrie ice machine patent model](https://www.si.edu/object/nmah_846192); [Britannica: John Gorrie](https://www.britannica.com/biography/John-Gorrie)

## Chapter IV · Cold for everyone

### Cold beer first
*Chapter IV · Cold for everyone*

Industry adopts the machine.

Industry came first. In 1876, the German engineer Carl von Linde built an ammonia compressor for a brewery in Trieste, so lager could be brewed even in summer. Ammonia works well, but it is toxic, and so were the other early refrigerants.

![A flywheel and compressor beside lager casks, in the style of an old photograph. AI-generated illustration.](https://assets.planetpast.com/a/f0/f0eeee3a53289359.jpg)

- **1876**: built for the Dreher brewery, Trieste
- **32 years**: in service, until 1908
- **< 9 °C**: needed to brew lager

Chapter IV · Cold for everyone

#### Linde’s ammonia machine

Cooling Post: Carl von Linde’s 1875 methyl-ether machine leaked; in 1876 he built an ammonia compressor at Maschinenfabrik Augsburg for the Dreher brewery in Trieste, in use until 1908. It allowed summer lager brewing; lager needs temperatures below 9 °C. Britannica and the IIR: Ferdinand Carré built an ammonia–water absorption machine in 1859.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [Cooling Post: the first Linde ammonia chiller](https://www.coolingpost.com/features/first-linde-ammonia-chiller-takes-centre-stage); [Britannica: Refrigeration](https://www.britannica.com/technology/refrigeration); [International Institute of Refrigeration: A brief history of refrigeration (PDF)](https://efriarc.pt/wp-content/uploads/2022/09/IIR_A-Brief-History-of-Refrigeration.pdf)

### A fridge in the kitchen
*Chapter IV · Cold for everyone*

And the search for a safe refrigerant.

Home refrigerators followed. A famous American model of 1927 carried its round compressor on top, and its price soon fell from more than five hundred dollars to about two hundred. But they still used toxic gases. In 1930, a team led by the chemist Thomas Midgley announced a safer one: a chlorofluorocarbon, or CFC. To show it was safe to breathe, Midgley inhaled it and blew out a candle.

![A 1920s-style kitchen fridge on legs, its machinery in a round turret. AI-generated illustration.](https://assets.planetpast.com/a/fe/fe5051fa2afef9d9.jpg)

- 1910 GE Dumbbell: $1,000
- 1927 at launch: ≈$525
- a few years later: ≈$200

- ammonia: toxic
- sulfur dioxide: toxic
- methyl chloride: toxic
- 1930: dichlorodifluoromethane, a CFC

- **Apr 1930**: announced to chemists in Atlanta
- **1931**: R-12 on the market

Chapter IV · Cold for everyone

#### The home fridge and CFCs

Albany Institute: GE’s first home unit, the 1910 “Dumbbell”, cost $1,000; its 1927 Monitor Top cost about $525 and fell to about $200 within a few years. EBSCO: in 1930 domestic refrigerants were ammonia, sulfur dioxide and methyl chloride, all toxic; Thomas Midgley’s team at Frigidaire and General Motors made dichlorodifluoromethane and announced it at the American Chemical Society meeting in Atlanta in April 1930; EBSCO dates his candle demonstration, in which he inhaled the gas and blew out a candle, to 1937, and accounts of it vary. The IIR dates the first fluorocarbons to 1930 and the market launch of R-12 to 1931.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [Albany Institute of History & Art: GE Monitor Top refrigerator](https://albanyinstitute.org/online-exhibition/50-objects/section/ge-monitor-top-refrigerator); [EBSCO Research Starters: Midgley introduces dichlorodifluoromethane refrigerant gas](https://ebsco.com/research-starters/history/midgley-introduces-dichlorodifluoromethane-refrigerant-gas); [International Institute of Refrigeration: A brief history of refrigeration (PDF)](https://efriarc.pt/wp-content/uploads/2022/09/IIR_A-Brief-History-of-Refrigeration.pdf)

### Changing the fluid, twice
*Chapter IV · Cold for everyone*

From CFCs to HFCs to natural refrigerants.

But CFCs had a hidden cost. In 1974, Mario Molina and Sherwood Rowland showed they could release chlorine high in the atmosphere. In 1985, the ozone hole was reported over Antarctica. The Montreal Protocol of 1987, ratified by all 197 parties, phased CFCs out. Their replacements, hydrofluorocarbons or HFCs, spare the ozone but trap heat, so the Kigali Amendment of 2016 cuts them by over eighty percent in about thirty years. Many fridges now use isobutane, which warms the planet only a tiny fraction as much as the HFC it replaced.

- 1974: Molina and Rowland: CFCs carry chlorine up
- 1985: ozone hole reported
- 1987: Montreal Protocol: universally ratified (197 parties)
- 2016: Kigali: HFCs cut >80% over about 30 years

![Discarded fridges wait so their refrigerant can be recovered before scrapping. AI-generated illustration.](https://assets.planetpast.com/a/2f/2f00824e703c04fa.jpg)

![Many European supermarkets now chill with carbon dioxide, GWP 1, at high pressure. AI-generated illustration.](https://assets.planetpast.com/a/e7/e7464d2e1ba64f7e.jpg)

- HFC-134a: ≈1,430
- isobutane R-600a: 8
- propane R-290: 3

Chapter IV · Cold for everyone

#### Ozone, climate and new refrigerants

Britannica: Molina and Rowland (1974) identified CFCs as a source of stratospheric chlorine; Farman, Gardiner and Shanklin of the British Antarctic Survey reported the ozone hole in 1985; Crutzen, Molina and Rowland shared the 1995 Nobel Prize in Chemistry. UNEP: the Montreal Protocol (1987) is universally ratified by 197 parties; the Kigali Amendment, adopted on 15 October 2016 and in force since 1 January 2019, cuts hydrofluorocarbons (HFCs) by more than 80% over about 30 years and could avoid up to 0.4 °C of warming by 2100. US EPA (2011): global-warming potentials of 8 for isobutane (R-600a), 3 for propane (R-290) and about 1,430 for HFC-134a; both hydrocarbons are highly flammable, so charge sizes are limited. EPA: CO₂ (R-744, GWP 1) is used in European and Australian supermarket systems.

This film keeps the ozone story short; PlanetPast’s film on the ozone layer tells it in full.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [Britannica: Ozone depletion](https://www.britannica.com/science/ozone-depletion); [UNEP Ozone Secretariat: the Montreal Protocol](https://ozone.unep.org/node/17); [UNEP Ozone Secretariat: the Kigali Amendment](https://ozone.unep.org/node/242); [US EPA, Federal Register (20 Dec 2011): hydrocarbon refrigerants in household and retail units](https://www.govinfo.gov/content/pkg/FR-2011-12-20/html/2011-32175.htm); [US EPA: HFC alternatives in commercial refrigeration (archived)](https://webarchive.library.unt.edu/web/20121010175744/http://www.epa.gov/ozone/downloads/EPA_HFC_ComRef.pdf)

## Chapter V · The cold chain

### The cold chain
*Chapter V · The cold chain*

Food, medicine and electricity.

Refrigeration now holds up modern life. According to the UN Environment Programme and the FAO, twelve percent of the world’s food is lost for lack of it. Vaccines in a fridge are kept between two and eight degrees. One warm link anywhere in the chain can spoil everything that passes through it. The International Institute of Refrigeration estimates that refrigeration, air conditioning and heat pumps together use about a fifth of the world’s electricity. And according to ASEAN Briefing, Thailand was the world’s third-largest exporter of air conditioners in 2024.

![UNEP and FAO put the loss at 526 million tonnes of food a year (2022). AI-generated illustration.](https://assets.planetpast.com/a/cb/cb21ddcd6a487f87.jpg)

![Vials on ice packs: the CDC range for vaccines in a fridge is 2 to 8 °C. AI-generated illustration.](https://assets.planetpast.com/a/9b/9bdb718c704c21d8.jpg)

- **≈20%**: of world electricity: refrigeration, AC and heat pumps
- **≈5 bn**: systems in use worldwide

- **≈19 million**: air conditioners produced
- **US$7.0 bn**: air-conditioner exports

Chapter V · The cold chain

#### The cold chain

UNEP and FAO (12 November 2022): 526 million tonnes of food, 12% of global production, are lost for lack of refrigeration; the report calls sustainable cold chains critical to feeding the additional two billion people expected by 2050. CDC: vaccines are stored in a refrigerator at 2–8 °C. International Institute of Refrigeration (2019): about 5 billion refrigeration, air-conditioning and heat-pump systems use about 20% of the world’s electricity. IEA (2018): air conditioners and electric fans alone use about 10% of global electricity. ASEAN Briefing: in 2024 Thailand was the world’s third-largest air-conditioner exporter, after China and Mexico, with exports of US$7.04 billion from about 19 million units. EGAT’s Label No. 5 began with refrigerators; the air-conditioner label started on 20 September 1994 (IEA policy database), and EGAT marked 30 years of the scheme in 2025.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [UNEP/FAO via EurekAlert (12 Nov 2022): sustainable food cold chains](https://www.eurekalert.org/news-releases/971095); [CDC: vaccine storage temperatures (PDF)](https://www.CDC.gov/infectioncontrol/pdf/QUOTS/Environment-of-Care-Vaccine-Storage-Area-P.pdf); [International Institute of Refrigeration (2019): the role of refrigeration in the global economy](https://iifiir.org/en/news/new-iir-informatory-note-on-the-role-of-refrigeration-in-the-global-economy-ba8bd933-a1dd-4710-a4ef-9794ec0c063d); [IEA (2018): The Future of Cooling](https://www.iea.org/news/air-conditioning-use-emerges-as-one-of-the-key-drivers-of-global-electricity-demand-growth); [ASEAN Briefing: Thailand, a global leader in air-conditioner manufacturing and export](https://www.aseanbriefing.com/news/thailand-a-global-leader-in-air-conditioner-manufacturing-and-export/); [IEA policies database: Energy Efficiency Label No. 5, air conditioner](https://prod.iea.org/policies/1583-energy-efficiency-label-no5-air-conditioner); [EGAT (2025): 30 years of Label No. 5](https://www.egat.co.th/home/en/?p=19566)

### A brain on the network
*Chapter V · The cold chain*

Why the warning matters, and what it advises.

The newest part of a commercial system is its controller. It holds the temperature, raises alarms, and runs defrosting, briefly warming the cold coil to melt its ice. Those exposed to the internet are the targets. Someone who reaches one can change its setpoint or force a heating or defrost cycle, and the food or medicine inside warms. In November’s second wave, some units reached fifty degrees. The agencies’ advice is plain: keep controllers off the public internet, change default passwords, and keep the software up to date.

![A cold-room controller beside a frosted door, its warning light on. AI-generated illustration.](https://assets.planetpast.com/a/99/991be7bab1ce2ce1.jpg)

- **115+**: stores hit
- **6**: European countries

- take controllers off the public internet
- remote access only through a secured firewall or VPN
- change default passwords, use multi-factor login
- patch firmware; set safe temperature limits and alarms

Chapter V · The cold chain

#### What the agencies advise

Help Net Security and BleepingComputer (5–6 November 2026): attackers can change setpoints or force units into heating or defrost, leading to “widespread inventory loss and equipment hazards”. A second wave in November hit more than 115 stores in six European countries, some units reaching 50 °C. Recommended: remove controllers from the public internet; put remote access behind a secured firewall or VPN; change default passwords and use multi-factor authentication; patch firmware and replace unsupported devices; separate operational networks from business networks; set safe temperature limits, keep logs and alerts, and keep offline backups.

The model’s setpoint and temperatures are illustrative and show only the effect described in the advisory.

The 3D scenes are simplified teaching models, not to scale; temperatures and colours in them are illustrative.

Sources: [Help Net Security (6 Nov 2026): US agencies warn attackers are targeting refrigeration systems that protect food and medicine](https://www.helpnetsecurity.com/2026/11/06/cyberattacks-refrigeration-systems-cisa-fbi/); [BleepingComputer (5 Nov 2026): FBI, CISA warn of cyberattacks targeting refrigeration systems](https://www.bleepingcomputer.com/news/security/fbi-cisa-warn-of-cyberattacks-targeting-refrigeration-systems/); [Cybersecurity Dive: refrigeration attacks in France](https://www.cybersecuritydive.com/news/refrigeration-france-cyber/832858/)

## Epilogue

### Carrying heat away
*Epilogue*

Timeline and sources.

Cold is never made. It is heat carried away, all day and all night, by machines that someone has to tell how hard to work. It began in a Glasgow laboratory, grew up on brewery floors, and now guards our food, our medicines and our blood. So keeping things cold now also means keeping control of the small boxes that give those orders.

- 1748: Cullen’s evaporation experiment
- 1806: Tudor’s first ice cargo
- 1834: Perkins’s vapour-compression patent
- 1876: Linde’s ammonia compressor
- 1927–1930: home fridges; CFCs announced
- 1987, 2016: Montreal Protocol; Kigali Amendment
- 2026: warning on networked controllers

![The cold coil and the hot coil: two ends of one loop. AI-generated illustration.](https://assets.planetpast.com/a/0a/0a773a2e32f7e4ec.jpg)

- heat flows hot → cold unless work pushes it
- evaporating takes heat; condensing gives it back
- pressure decides where a liquid boils

Epilogue · Sources

#### Sources

Every fact in this film comes from the sources below. Where sources give different dates (Cullen 1748 or 1755; Perkins 1834 or 1835), both are named in the panels. The chapter stills and pictures are AI-generated illustrations and show no real people or products. The fridge, the molecules and the cold chain are simplified teaching models; temperatures in them are illustrative. Security advice is given in general terms only, as the agencies published it.

Sources: [BleepingComputer (5 Nov 2026): FBI, CISA warn of cyberattacks targeting refrigeration systems](https://www.bleepingcomputer.com/news/security/fbi-cisa-warn-of-cyberattacks-targeting-refrigeration-systems/); [Help Net Security (6 Nov 2026): US agencies warn attackers are targeting refrigeration systems that protect food and medicine](https://www.helpnetsecurity.com/2026/11/06/cyberattacks-refrigeration-systems-cisa-fbi/); [Cybersecurity Dive: refrigeration attacks in France](https://www.cybersecuritydive.com/news/refrigeration-france-cyber/832858/); [OpenStax College Physics 15.5: Heat pumps and refrigerators](https://openstax.org/books/college-physics/pages/15-5-applications-of-thermodynamics-heat-pumps-and-refrigerators); [OpenStax College Physics 2e, 14.3: Phase change and latent heat](https://openstax.org/books/college-physics-ap-courses-2e/pages/14-3-phase-change-and-latent-heat); [OpenStax University Physics vol. 2, 1.5: Phase changes](https://openstax.org/books/university-physics-volume-2/pages/1-5-phase-changes); [Penn State EGEE 102, 6.4: Refrigerators](https://courses.ems.psu.edu/egee102/node/2402); [Britannica: Refrigeration](https://www.britannica.com/technology/refrigeration); [International Institute of Refrigeration: A brief history of refrigeration (PDF)](https://efriarc.pt/wp-content/uploads/2022/09/IIR_A-Brief-History-of-Refrigeration.pdf); [HistoryNet: how pioneering entrepreneurs helped 19th-century America keep cool](https://www.historynet.com/how-pioneering-entrepreneurs-helped-19th-century-america-keep-cool/); [ASME Landmark 274: Perkins vapour-compression cycle for refrigeration](https://www.asme.org/about-asme/engineering-history/landmarks/274-perkins-vapor-compression-cycle-for-refrigeration); [Smithsonian National Museum of American History: Gorrie ice machine patent model](https://www.si.edu/object/nmah_846192); [Cooling Post: the first Linde ammonia chiller](https://www.coolingpost.com/features/first-linde-ammonia-chiller-takes-centre-stage); [Albany Institute of History & Art: GE Monitor Top refrigerator](https://albanyinstitute.org/online-exhibition/50-objects/section/ge-monitor-top-refrigerator); [EBSCO Research Starters: Midgley introduces dichlorodifluoromethane refrigerant gas](https://ebsco.com/research-starters/history/midgley-introduces-dichlorodifluoromethane-refrigerant-gas); [Britannica: Ozone depletion](https://www.britannica.com/science/ozone-depletion); [UNEP Ozone Secretariat: the Montreal Protocol](https://ozone.unep.org/node/17); [UNEP Ozone Secretariat: the Kigali Amendment](https://ozone.unep.org/node/242); [US EPA, Federal Register (20 Dec 2011): hydrocarbon refrigerants in household and retail units](https://www.govinfo.gov/content/pkg/FR-2011-12-20/html/2011-32175.htm); [US EPA: HFC alternatives in commercial refrigeration (archived)](https://webarchive.library.unt.edu/web/20121010175744/http://www.epa.gov/ozone/downloads/EPA_HFC_ComRef.pdf); [UNEP/FAO via EurekAlert (12 Nov 2022): sustainable food cold chains](https://www.eurekalert.org/news-releases/971095); [International Institute of Refrigeration (2019): the role of refrigeration in the global economy](https://iifiir.org/en/news/new-iir-informatory-note-on-the-role-of-refrigeration-in-the-global-economy-ba8bd933-a1dd-4710-a4ef-9794ec0c063d); [IEA (2018): The Future of Cooling](https://www.iea.org/news/air-conditioning-use-emerges-as-one-of-the-key-drivers-of-global-electricity-demand-growth); [CDC: vaccine storage temperatures (PDF)](https://www.CDC.gov/infectioncontrol/pdf/QUOTS/Environment-of-Care-Vaccine-Storage-Area-P.pdf); [ASEAN Briefing: Thailand, a global leader in air-conditioner manufacturing and export](https://www.aseanbriefing.com/news/thailand-a-global-leader-in-air-conditioner-manufacturing-and-export/); [IEA policies database: Energy Efficiency Label No. 5, air conditioner](https://prod.iea.org/policies/1583-energy-efficiency-label-no5-air-conditioner); [EGAT (2025): 30 years of Label No. 5](https://www.egat.co.th/home/en/?p=19566)

